NA-27/Á֯ļöºÐ¼®°è
  • »óǰ°¡ 7,227,000¿ø

¼ö·® +1 -1

  • ¼±ÅÃÇϽŠ»óǰÀº °í°´¼¾ÅÍ·Î ¹®ÀÇÁÖ¼¼¿ä.

½Ç½Ã°£ 1/1 1/3 ¿ÁŸºê¹êµå ÃøÁ¤±â (NA-27)
ȯ°æºÎ Çü½Ä ½ÂÀÎ Á¦Ç° (NESM-64/65)

 

Ư¡

ÀûºÐÇü Á¤¹Ð ¼ÒÀ½°è·Î °è·®¹ý, JIS ¹× IEC ±Ô°Ý¿¡
ÀûÇÕ (ÇϳªÀÇ ¸¶ÀÌÅ©·ÎÆù Ãâ·Â½ÅÈ£¿¡ ´ëÇØ ´Ù¸¥ µ¿Æ¯¼º Á֯ļö ¿þÀÌÆÃ Á¶°ÇÀ» ±âº»À¸·Î ´Ù¾çÇÑ ¸ðµå
µ¿½Ã°èÃø)
1/1 & 1/3 ¿ÁŸºê¹êµå Real-time ºÐ¼®
(1/3 ¿ÁŸºê : 12.5 Hz ~ 12.5 KHz
1/1 ¿ÁŸºê : 16Hz ~ 8 KHz)
ÀÜÇ⠽ð£ ÃøÁ¤ (¼öÄ¡ ¹× ±×·¡ÇÁ·Î µ¿½ÃÇ¥½Ã)
ÃøÁ¤¸ðµå : Lp, Leq, LE, Lmax, Lmin, Lpeak, Lx,
Impulse, Ltm3, Ltm5, P_AVE, P_SUM, REVERB
º»Ã¤³Î, º¸Á¶Ã¤³Î·Î µÎ °¡Áö ¸ðµå ½Ç½Ã°£ µ¿½Ã ÃøÁ¤ °¡´É
»ç¿ë ¿ëµµ Æí¸®¿¡ µû¶ó Á¶°ÇºÎ Start & Stop ±â´É
(¿ÜºÎÆ®¸®°Å, ·¹º§Æ®¸®°Å, ½Ã°£Æ®¸®°Å)
Àû¿Ü¼± ¸®¸ðÄÁ¿¡ ÀÇÇØ¼­ ¿ø°ÝÁ¶ÀÛ °¡´É
±¤Åë½Å Port¿¡ ÀÇÇØ¼­ PC¸¦ »ç¿ëÇÑ µ¥ÀÌÅÍ ¼öÁý
(NA-Software)

 

 

 

Applicable standards IEC 651 : 1979 Type 1, IEC 804 : 1985 Type 1, JIS C 1505-1988
JIS C 1513-1983 Type ¥², ANSI SI. 11 Type 1D, IEC 1260-1995
Microphone and preamplifier  1/2-inch prepolarized condenser microphone UC-53A and
preamplifier NH-20
Dual Measurement and real-time frequency analyser Main and sub
Individual frequency weighting and time weighting settings are possible for main and sub channels. 1/1, or 1/3 octave band real-time frequency analysis capability in main channel.
¡¡
Measurement functions Instantaneous sound pressure level (Lp)
Equivalent continuous sound pressure level (Leq)
Sound exposure level (LE)
Maximum and minimum sound pressure level (Lmax and Lmin)
Percetile sound pressure level (5 values selectable from L1, L5,
L10, L50, L90, L95, L99)
Takt-max sound pressure level (Ltm3, Ltm5)*
Wavefrom peak hold (Lpeak)*
*sub channel only
Measurement time (except for instantaneou sound pressure level Lp)
Presetting from 1 to 99 (units : h, m, s)
Manual measurement by start and stop (max. 99 h)
Lx requires more than 10 s setting.
Max. measurement level 140 dB rms, 133dB at c.f.3, 143 dB peak for peak hold
Noise floor Typical 17dB (A) rms
Frequency range 20 - 12500 Hz (including microphone)
10 - 20000 Hz (electrical characteristics)
Frequency weighting A, C, Flat (main and sub channels)
Time weighting Main channel : Fast, Slow, 35ms, 10ms
Sub channel : Fast, Slow, 35 ms, 10 ms, Impulse, Peak hold
Display Backlit LCD panel (192 x 192 dots)
Sound level meter display
Numerical : 4 digits, update cycle 1 s, resolution 0.1 dB
Bar graph* : Scale range 60 dB in 0.5-dB steps, update cycle 0.1s
Analyzer display
Numerical : 4 digits, update cyle 1 s, resolution 0.1 dB
Bargraph* : Scale range 70 dB in 0.5-dB steps, update cycle 0.1s
Level-time : Min. 120 address, Max. all address
*main channel only
Real-time clock : Year, Month, Day, Hour, Minute, Second
Level range Sound level meter mode (Display range : 60 dB)
7 range in 10-dB steps : 20 - 80, 30 - 90, 40 - 100, 50 - 110,
;60- 120, 70 - 130, 80 - 140 dB
Analyer mode (Display range : 70 dB)
7 ranges in 10-dB steps : 10 - 80, 20 - 90, 30 - 100, 40 - 110,
;50 - 120, 60 - 130, 70 - 140 dB
Memory Manual and auto store modes for instantaneous values and processing results
1 block for manual store mode, 2 block for auto store mode
Manual :  all measurement data to be store
 Capacity : 200 data
Auto :
Single store : Selected data to be stored continuously
 Capacity : 10000 data (sound level meter mode)
;4000 data (1/1 oct. analysis)
;2000 data (1/3 oct. analysis)
Group store : All measurement data to be stored continously Capacity : 200 group data
¡¡
Trigger function Trigger source : Input signal, External signal, Time dat
Time display function Processing start can be desplayed by 1 to 10 s
Pause function Normal pause function and back-erase function to delete data acquired 1 to 5 s before
Infrared rays communication Data transmission with a PC
Remote control by an infrared rays controller (NA27RC1)
Printout function (Optional printer CP-10, CP-11)
Single mode : One current data on screen or one data stored
on memory
Successive mode : Successive data at designated address area
Signal output AC output (for main and sub channels)
DC output (for one channel only, selected by menu)
External trigger input
Serial interface : RS-232-C 9 pin D-sub
Infrared rays data transmission : Max. 50 cm
Infrared rays remote control : Max. 3 m
Power requirements 4 to 6 V DC, approx. 320 mA (at 5 V, 1/3 oct analysis mode, 20¡É)
Battery : Four IEC R14P (size "C") batteries
 Life : Approx. 8 h (alkaline batteries, continuous operation,
 1/3 oct. analysis)
AC adapter : AC adapter NC-94, 100 to 240 V (option)
Power cable : AA-38-222 (option)
Ambient conditions for - 10 to + 50 ¡É, 30 to 90% RH
operation
Dimensions, weight Approx. 30 (H) x 10 (W) x 5 (D) cm, approx. 800g (including batteries)
Supplied accessories Windscreen x 1, Carrying case x 1, Tripod adapter x 1,
IEC R6 batteries x 4, Lithium battery CR-1/3Nx 1,