½Ç½Ã°£ 1/1 1/3 ¿ÁŸºê¹êµå ÃøÁ¤±â (NA-27)
ȯ°æºÎ Çü½Ä ½ÂÀÎ Á¦Ç° (NESM-64/65)
Ư¡
![]() |
ÀûºÐÇü Á¤¹Ð ¼ÒÀ½°è·Î °è·®¹ý, JIS ¹× IEC ±Ô°Ý¿¡ ÀûÇÕ (ÇϳªÀÇ ¸¶ÀÌÅ©·ÎÆù Ãâ·Â½ÅÈ£¿¡ ´ëÇØ ´Ù¸¥ µ¿Æ¯¼º Á֯ļö ¿þÀÌÆÃ Á¶°ÇÀ» ±âº»À¸·Î ´Ù¾çÇÑ ¸ðµå µ¿½Ã°èÃø) |
![]() |
1/1 & 1/3 ¿ÁŸºê¹êµå Real-time ºÐ¼® (1/3 ¿ÁŸºê : 12.5 Hz ~ 12.5 KHz 1/1 ¿ÁŸºê : 16Hz ~ 8 KHz) |
![]() |
ÀÜÇ⠽ð£ ÃøÁ¤ (¼öÄ¡ ¹× ±×·¡ÇÁ·Î µ¿½ÃÇ¥½Ã) |
![]() |
ÃøÁ¤¸ðµå : Lp, Leq, LE, Lmax, Lmin, Lpeak, Lx, Impulse, Ltm3, Ltm5, P_AVE, P_SUM, REVERB |
![]() |
º»Ã¤³Î, º¸Á¶Ã¤³Î·Î µÎ °¡Áö ¸ðµå ½Ç½Ã°£ µ¿½Ã ÃøÁ¤ °¡´É |
![]() |
»ç¿ë ¿ëµµ Æí¸®¿¡ µû¶ó Á¶°ÇºÎ Start & Stop ±â´É (¿ÜºÎÆ®¸®°Å, ·¹º§Æ®¸®°Å, ½Ã°£Æ®¸®°Å) |
![]() |
Àû¿Ü¼± ¸®¸ðÄÁ¿¡ ÀÇÇØ¼ ¿ø°ÝÁ¶ÀÛ °¡´É |
![]() |
±¤Åë½Å Port¿¡ ÀÇÇØ¼ PC¸¦ »ç¿ëÇÑ µ¥ÀÌÅÍ ¼öÁý (NA-Software) |
Applicable standards | IEC 651 : 1979 Type 1, IEC 804 : 1985 Type 1, JIS C 1505-1988 |
JIS C 1513-1983 Type ¥², ANSI SI. 11 Type 1D, IEC 1260-1995 | |
Microphone and preamplifier | 1/2-inch prepolarized condenser microphone UC-53A and |
preamplifier NH-20 | |
Dual Measurement and real-time frequency analyser | Main and sub |
Individual frequency weighting and time weighting settings are possible for main and sub channels. 1/1, or 1/3 octave band real-time frequency analysis capability in main channel. | |
¡¡ | |
Measurement functions | Instantaneous sound pressure level (Lp) |
Equivalent continuous sound pressure level (Leq) | |
Sound exposure level (LE) | |
Maximum and minimum sound pressure level (Lmax and Lmin) | |
Percetile sound pressure level (5 values selectable from L1, L5, | |
L10, L50, L90, L95, L99) | |
Takt-max sound pressure level (Ltm3, Ltm5)* | |
Wavefrom peak hold (Lpeak)* | |
*sub channel only | |
Measurement time | (except for instantaneou sound pressure level Lp) |
Presetting from 1 to 99 (units : h, m, s) | |
Manual measurement by start and stop (max. 99 h) | |
Lx requires more than 10 s setting. | |
Max. measurement level | 140 dB rms, 133dB at c.f.3, 143 dB peak for peak hold |
Noise floor | Typical 17dB (A) rms |
Frequency range | 20 - 12500 Hz (including microphone) |
10 - 20000 Hz (electrical characteristics) | |
Frequency weighting | A, C, Flat (main and sub channels) |
Time weighting | Main channel : Fast, Slow, 35ms, 10ms |
Sub channel : Fast, Slow, 35 ms, 10 ms, Impulse, Peak hold | |
Display | Backlit LCD panel (192 x 192 dots) |
Sound level meter display | |
Numerical : 4 digits, update cycle 1 s, resolution 0.1 dB | |
Bar graph* : Scale range 60 dB in 0.5-dB steps, update cycle 0.1s | |
Analyzer display | |
Numerical : 4 digits, update cyle 1 s, resolution 0.1 dB | |
Bargraph* : Scale range 70 dB in 0.5-dB steps, update cycle 0.1s | |
Level-time : Min. 120 address, Max. all address | |
*main channel only | |
Real-time clock : Year, Month, Day, Hour, Minute, Second | |
Level range | Sound level meter mode (Display range : 60 dB) |
7 range in 10-dB steps : 20 - 80, 30 - 90, 40 - 100, 50 - 110, | |
;60- 120, 70 - 130, 80 - 140 dB | |
Analyer mode (Display range : 70 dB) | |
7 ranges in 10-dB steps : 10 - 80, 20 - 90, 30 - 100, 40 - 110, | |
;50 - 120, 60 - 130, 70 - 140 dB | |
Memory | Manual and auto store modes for instantaneous values and processing results |
1 block for manual store mode, 2 block for auto store mode | |
Manual : all measurement data to be store | |
Capacity : 200 data | |
Auto : | |
Single store : Selected data to be stored continuously | |
Capacity : 10000 data (sound level meter mode) | |
;4000 data (1/1 oct. analysis) | |
;2000 data (1/3 oct. analysis) | |
Group store : All measurement data to be stored continously Capacity : 200 group data | |
¡¡ | |
Trigger function | Trigger source : Input signal, External signal, Time dat |
Time display function | Processing start can be desplayed by 1 to 10 s |
Pause function | Normal pause function and back-erase function to delete data acquired 1 to 5 s before |
Infrared rays communication | Data transmission with a PC |
Remote control by an infrared rays controller (NA27RC1) | |
Printout function | (Optional printer CP-10, CP-11) |
Single mode : One current data on screen or one data stored | |
on memory | |
Successive mode : Successive data at designated address area | |
Signal output | AC output (for main and sub channels) |
DC output (for one channel only, selected by menu) | |
External trigger input | |
Serial interface : RS-232-C 9 pin D-sub | |
Infrared rays data transmission : Max. 50 cm | |
Infrared rays remote control : Max. 3 m | |
Power requirements | 4 to 6 V DC, approx. 320 mA (at 5 V, 1/3 oct analysis mode, 20¡É) |
Battery : Four IEC R14P (size "C") batteries | |
Life : Approx. 8 h (alkaline batteries, continuous operation, | |
1/3 oct. analysis) | |
AC adapter : AC adapter NC-94, 100 to 240 V (option) | |
Power cable : AA-38-222 (option) | |
Ambient conditions for | - 10 to + 50 ¡É, 30 to 90% RH |
operation | |
Dimensions, weight | Approx. 30 (H) x 10 (W) x 5 (D) cm, approx. 800g (including batteries) |
Supplied accessories | Windscreen x 1, Carrying case x 1, Tripod adapter x 1, |
IEC R6 batteries x 4, Lithium battery CR-1/3Nx 1, | |
Remote controller x 1, Miniature screwdriver x 1, | |
Instruction manual x 1 |
450,000¿ø
4,400,000¿ø
1,150,000¿ø
4,550,000¿ø
3,025,000¿ø
29,700,000¿ø
5,560,000¿ø
330,000¿ø